DIGITAL_CHANNELS_MSO2X

Download Flojoy Studio to try this app
Set the digital MSO2XX channels on (1) or off (0). Requires a CONNECT_MSO2X block to create the connection. Tested on MSO22 and MSO24. Params: connection : VisaConnection The VISA address (requires the CONNECTION_MSO2X block). all_channels : bool, default=False Turn all channels on? The display parameters aren't used if True. D0_display : select, default=0 Turn the channel on (1) or off (0). D1_display : select, default=0 Turn the channel on (1) or off (0). D2_display : select, default=0 Turn the channel on (1) or off (0). D3_display : select, default=0 Turn the channel on (1) or off (0). D4_display : select, default=0 Turn the channel on (1) or off (0). D5_display : select, default=0 Turn the channel on (1) or off (0). D6_display : select, default=0 Turn the channel on (1) or off (0). D7_display : select, default=0 Turn the channel on (1) or off (0). D8_display : select, default=0 Turn the channel on (1) or off (0). D9_display : select, default=0 Turn the channel on (1) or off (0). D10_display : select, default=0 Turn the channel on (1) or off (0). D11_display : select, default=0 Turn the channel on (1) or off (0). D12_display : select, default=0 Turn the channel on (1) or off (0). D13_display : select, default=0 Turn the channel on (1) or off (0). D14_display : select, default=0 Turn the channel on (1) or off (0). D15_display : select, default=0 Turn the channel on (1) or off (0). D16_display : select, default=0 Turn the channel on (1) or off (0). Returns: out : String Channel display
Python Code
from typing import Optional
from flojoy import VisaConnection, flojoy, DataContainer, String


def to_bit(channel):
    channel = 1 if channel else 0
    return channel


@flojoy(deps={"tm_devices": "1"}, inject_connection=True)
def DIGITAL_CHANNELS_MSO2X(
    connection: VisaConnection,
    input: Optional[DataContainer] = None,
    all_channels: bool = False,
    D0_display: bool = False,
    D1_display: bool = False,
    D2_display: bool = False,
    D3_display: bool = False,
    D4_display: bool = False,
    D5_display: bool = False,
    D6_display: bool = False,
    D7_display: bool = False,
    D8_display: bool = False,
    D9_display: bool = False,
    D10_display: bool = False,
    D11_display: bool = False,
    D12_display: bool = False,
    D13_display: bool = False,
    D14_display: bool = False,
    D15_display: bool = False,
) -> String:
    """Set the digital MSO2XX channels on (1) or off (0).

    Requires a CONNECT_MSO2X block to create the connection.

    Tested on MSO22 and MSO24.

    Parameters
    ----------
    connection : VisaConnection
        The VISA address (requires the CONNECTION_MSO2X block).
    all_channels : bool, default=False
        Turn all channels on? The display parameters aren't used if True.
    D0_display : select, default=0
        Turn the channel on (1) or off (0).
    D1_display : select, default=0
        Turn the channel on (1) or off (0).
    D2_display : select, default=0
        Turn the channel on (1) or off (0).
    D3_display : select, default=0
        Turn the channel on (1) or off (0).
    D4_display : select, default=0
        Turn the channel on (1) or off (0).
    D5_display : select, default=0
        Turn the channel on (1) or off (0).
    D6_display : select, default=0
        Turn the channel on (1) or off (0).
    D7_display : select, default=0
        Turn the channel on (1) or off (0).
    D8_display : select, default=0
        Turn the channel on (1) or off (0).
    D9_display : select, default=0
        Turn the channel on (1) or off (0).
    D10_display : select, default=0
        Turn the channel on (1) or off (0).
    D11_display : select, default=0
        Turn the channel on (1) or off (0).
    D12_display : select, default=0
        Turn the channel on (1) or off (0).
    D13_display : select, default=0
        Turn the channel on (1) or off (0).
    D14_display : select, default=0
        Turn the channel on (1) or off (0).
    D15_display : select, default=0
        Turn the channel on (1) or off (0).
    D16_display : select, default=0
        Turn the channel on (1) or off (0).

    Returns
    -------
    String
        Channel display
    """

    # Retrieve oscilloscope instrument connection
    scope = connection.get_handle()

    if all_channels:
        scope.write("DISplay:WAVEView1:DCH1_DALL:STATE 1")
    else:
        scope.write(f"DISplay:WAVEView1:DCH1_D0:STATE {to_bit(D0_display)}")
        scope.write(f"DISplay:WAVEView1:DCH1_D1:STATE {to_bit(D1_display)}")
        scope.write(f"DISplay:WAVEView1:DCH1_D2:STATE {to_bit(D2_display)}")
        scope.write(f"DISplay:WAVEView1:DCH1_D3:STATE {to_bit(D3_display)}")
        scope.write(f"DISplay:WAVEView1:DCH1_D4:STATE {to_bit(D4_display)}")
        scope.write(f"DISplay:WAVEView1:DCH1_D5:STATE {to_bit(D5_display)}")
        scope.write(f"DISplay:WAVEView1:DCH1_D6:STATE {to_bit(D6_display)}")
        scope.write(f"DISplay:WAVEView1:DCH1_D7:STATE {to_bit(D7_display)}")
        scope.write(f"DISplay:WAVEView1:DCH1_D8:STATE {to_bit(D8_display)}")
        scope.write(f"DISplay:WAVEView1:DCH1_D9:STATE {to_bit(D9_display)}")
        scope.write(f"DISplay:WAVEView1:DCH1_D10:STATE {to_bit(D10_display)}")
        scope.write(f"DISplay:WAVEView1:DCH1_D11:STATE {to_bit(D11_display)}")
        scope.write(f"DISplay:WAVEView1:DCH1_D12:STATE {to_bit(D12_display)}")
        scope.write(f"DISplay:WAVEView1:DCH1_D13:STATE {to_bit(D13_display)}")
        scope.write(f"DISplay:WAVEView1:DCH1_D14:STATE {to_bit(D14_display)}")
        scope.write(f"DISplay:WAVEView1:DCH1_D15:STATE {to_bit(D15_display)}")

    return String(s="Digital display")

Find this Flojoy Block on GitHub

Example App

Having problems with this example app? Join our Discord community and we will help you out!
React Flow mini map

This app uses the Tektronix tm_measure library to decode I2C using a Tektronix MSO24 oscilloscope.

First the necessary blocks were added:

  • 1 CONNECT_MSO2X
  • 1 I2C_TRIGGER_MSO2X
  • 1 SINGLE_TRIGGER_MSO2X
  • 1 DECODE_I2C_MSO2X
  • 1 TEXT_VIEW

Each of these blocks must change the connection parameter to the correct instrument. The parameters were changed to match the setup: the clock_channel and data_channel parameters were changed to the proper analog or digital channel. The I2C_TRIGGER_MSO2X parameters were changed to trigger on the corrent signal. For example:

  • condition = address
  • addr_bits = 7
  • addr = 0010

therefore the actual address will be XXX0010 where X corresponds to a wildcard (0 or 1).

The blocks were connected as shown and the app was run.